标准编号:ISO/TR 52016-2:2017
中文名称:建筑物的能效 加热和冷却能源需求、内部温度、智能和潜热负荷 第2部分:ISO 52016-1和ISO 52017-1的解释和理由
英文名称:Energy performance of buildings — Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads — Part 2: Explanation and justification of ISO 52016-1 and ISO 52017-1
发布日期:2017-06
标准范围
This document contains information to support the correct understanding and use of ISO 52016-1 and
ISO 52017-1.
These documents give calculation methods for the assessment of:
— the (sensible and latent) energy load and need for heating and cooling, based on hourly calculations;
— the (sensible and latent) energy need for heating and cooling, based on monthly calculations
(ISO 52016-1);
— the internal temperature, based on hourly calculations; and
— the design (sensible and latent) heating and cooling load, based on hourly calculations.
This document does not contain any normative provisions.
NOTE A description of the rationale behind the reorganization of the cluster of strongly related and partly
overlapping ISO and CEN standards is given in Annex H.
标准预览图

