标准编号:ISO 8100-1:2019
中文名称:人员和货物运输用升降机 第1部分:乘客和货物乘客升降机
英文名称:Lifts for the transport of persons and goods — Part 1: Safety rules for the construction and installation of passenger and goods passenger lifts
发布日期:2019-03
标准范围
1.1 This document specifies the safety rules for permanently installed new passenger or goods
passenger lifts, with traction, positive or hydraulic drive, serving defined landing levels, having a car
designed for the transportation of persons or persons and goods, suspended by ropes, chains or jacks
and moving between guide rails inclined not more than 15° to the vertical.
1.2 In addition to the requirements of this document, supplementary requirements need to be
considered in special cases (use of lifts by persons with disabilities, in case of fire, potentially explosive
atmosphere, extreme climate conditions, seismic conditions, transporting dangerous goods, etc.).
1.3 This document does not cover:
a) lifts with:
1) drive systems other than those stated in 1.1;
2) rated speed less than or equal to 0,15 m/s;
b) hydraulic lifts:
1) with a rated speed exceeding 1 m/s;
2) where the setting of the pressure relief valve (5.9.3.5.3) exceeds 50 MPa;
1)
c) new passenger or goods passenger lifts in existing buildings where, in some circumstances due
to limitations enforced by building constraints, some requirements of this document cannot be met
and local requirements, e.g., EN 81-21 need to be considered;
d) lifting appliances, such as paternosters, mine lifts, theatrical lifts, appliances with automatic caging,
skips, lifts and hoists for building and public works sites, ships' hoists, platforms for exploration or
drilling at sea, construction and maintenance appliances or lifts in wind turbines;
e) important modifications (see Annex C) to a lift installed before this document is brought into
application;
f) safety during operations of transport, erection, repairs, and dismantling of lifts.
However, this document can usefully be taken as a basis.
Noise and vibrations are not dealt with in this document as they are not found at levels which could be
considered harmful with regard to the safe use and maintenance of the lift (see also 0.4.2).
1.4 This document is not applicable to passenger and goods passenger lifts, which are installed before
the date of its publication.